Standard basic use tipsYour location: Home >> News
Standard basic use tips
Time:2012/5/2 9:00:34 Click:2777 Back
Product Note:

Differ in substance from stainless steel and carbon steel, stainless steel has good ductility, and the improper use of lead can not unscrew the screw and nut with. Commonly known as "locked" or "killed".

To improve the lock from the following aspects to consider:
A. Correct choice of product:
(1) before use to confirm whether the mechanical properties of products can meet the requirements (such as the tensile strength of the bolts and nuts safe load);
(2) the length of the selection of the bolt should be appropriate to tighten the exposed nut 1-2 teeth away from the subject.
Two. Reduce the friction coefficient:
(1) The thread must be kept clean;
(2) prior to use proper lubricant (eg: 40 # oil, butter).
3. Correct method of operation:
(1) nut must be perpendicular to the screw axis of the rotary joint, do not tilt;
(2) tighten the process, the force must be uniform, force should not exceed the safe torque value (with safety torque table);
(3) If possible, choose a torque wrench or socket wrench, avoid the use of a spanner wrench or electric wrench;
(4) must be used under high temperature cooling, and do not use a rapidly rotating, avoid rapid temperature rise in the lock (such as electric wrench, etc.).
4. Safety torque reference table:
(1) the use of equipment: torque wrench, bench vice, matching sleeve:
(2) screw and nut performance levels:
Material: A2-70, 304
Tensile strength: 700N/mm2
Yield strength: 450 N/mm2,
(3) modes of operation: screw head vertical folder on a bench vice, sandwiched between a workpiece and a flat washer and a spring cushion, then put on a uniform force on the nut, as used to the force on the nut to achieve the following value, the nut can no longer be a smooth spin out.
(4) safety torque: Unit: N.m
Specifications of the M20-M18 is 2.5-2.5 the M16-2.0 M14 of Beta corolliflora-2.0 M12-1.75
Safety torque 22,018,015,010,055
1.5 the M8-1.25 specifications of the M10-M6-1.0
Safe torque 40409